The Intelligent Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated through the rotation of the resettable element, displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key. The Intelligent Manual Call Point will operate with compatible Apollo control equipment using the digital XP95, Discovery and CoreProtocols. - Resettable operating element - Easy access, front reset mechanism - E-Z fit connector system for installation - EN 54-11 & EN 54-17 Certified (Red version only) - 170° viewable LED - Continuity link for cable insulation testing - Suitable for semi flush or surface mounting
Apollo Fire Detectors Ltd
Website
Email Us
T: +44 2392 492 412
36 Brookside Road
PO9 1JR
Havant, Hampshire
United Kingdom
SOTERIA® Dimension is a range of sleek, flat optical fire detectors for flush mounting, using chamberless fire detection technology. The new range consists of an Optical Detector designed for commercial environments with high aesthetic requirements and a Specialist Optical Detector, designed for custodial ...
The SOTERIA® collection offers the next generation in fire recognition technology and has been developed to improve detection, reduce false alarms and deliver improved reliability. Complementing SOTERIA® is Apollo’s enhanced protocol, CoreProtocol®, the next generation in fire loop communication givi...
The new range, which meets EN 54-17 and EN 54-18 standards, is the latest addition to the range of CoreProtocol® enabled devices following the launch of the new Apollo SOTERIA® detectors earlier this year. All devices are backwards compatible but, when used with CoreProtocol®, provide enhanced functionalit...
The VAD has been developed as a primary or supplementary alarm device for use in situations where there is a risk that sounders will not be heard. This occurs, for example, where there is a high background noise e.g. in a workshop or a machine room. It might also be required where deaf or hearing impair...
The VAD has been developed as a primary or supplementary alarm device for use in situations where there is a risk that sounders will not be heard. This occurs, for example, where there is a high background noise e.g. in a workshop or a machine room. It might also be required where deaf or hearing impair...